Ubiquiti Networks MFI-MSW Datasheet Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
8
mFi
Wall Mount Motion Sensor
Jumper Settings
The mFi-MSW has jumpers located inside the product
casing. Typically there is no need to open the casing to
adjust the jumpers. The SENS and LED jumpers are the only
ones that you may want to change. The SENS jumper can
be changed to reduce the sensitivity of the microwave
sensor. The LED jumper can be turned on so the LED is
visible when the motion sensor is triggered. The LED
jumpercanbeturnedonpermanentlyortemporarilyfor
walk testing (testing the positioning of the sensor).
The following jumper settings are available:
Selection
ON OFF
NO/NC (Normally Open, Normally Closed)
This controls whether the alarm signal is
normally on or off. NC is the default setting and
should not be changed.
NC NO
SENS (Sensitivity) Set to Sensitive by default,
this controls the Microwave Sensor sensitivity.
Sensitivity is reduced when set to Standard.
Sensitive Standard
PIR (Passive Infrared Sensor) Enabled by
default. Removing the jumper will disable
this sensor.
Enabled Disabled
MW (Microwave Sensor) Enabled by default.
Removing the jumper will disable this sensor.
Enabled Disabled
AM (Anti-Mask) In the default disabled mode,
an alarm is triggered if both the PIR and MW
sensors are simultaneously triggered. When
enabled, an alarm will be triggered if the PIR
sensor is physically blocked and the MW sensor
detects an object four times continuously.
Enabled Disabled
LED LEDs are off by default.
ON OFF